NO one can get the cover off the darn thing. It spins easily by hand and doesnt make any noise. Make sure there is no water in the conduit from the timer to the pump, and breaker to timer. Improving air flow can also help, by trimming bushes or killing weeds, anything to let more breezes into the motor area. Mendorong partisipasi dunia dalam pengembangan teknologi jaringan baru, and vinylfor the first time ever on camera. EC65 uses 6 lbs, and EC75 uses 9 lbs, but since DE is half as light as others a lb of DE powder is more than 2 cups of dry measure, its actually closer to 4 cups. Tough one, good luck! I had a 1 hp pump and it went out and I bought a new Hayward super pump and hooked it up the same way as the other pump and I turn it on and it makes a loud noise and blows a fuse I double chew led everything and cant seem to find the problem, any ideas?? Impeller replacement is only ever really needed for breakage or other severe damage, so if it aint broke. Still no luck. Thanks for the reply! Also keep in mind that 1 lb of DE powder is not 16 oz of kitchen dry measure, but actually 32 oz (4 cups) of kitchen measure, because DE is so light and fluffy The normal unit of measure for 1 lb of DE powder is a 1 lb coffee can (or 4 8 oz cups). Juat replaced motor. Any suggestions? The motor has all of the same specifications of the Hayward motor that is being replaced, what could possibly cause the motor not ot work? We have tried switching outlets and that sometimes works. Hi Davy,I have a Hayward pump and its not priming.The basket is only filling up halfway with water. Then hold the shaft stationary to remove the impeller, and finally remove the housing. If power is reaching the motor, but nothing (no noise), look for any disconnected or severed wires in the back (shut off power first), if nothing, the motor may be dead. If its bulged, cracked or otherwise looks damaged, you can assume that it has failed. The Hayward swim profilter is making a loud noise and the top vibtrates. My 4 year old pump is working well so I am not looking to switch it, but I am curious if I should consider raising its location to above pool water level. "name": "Davy Merino",
I know I have power going to the unit, as I can hear it go on and off in the transformer, when I hit the switch. If flame is sensed with the gas valve off the control will go into lockout. Hi Joe, Low Flow would be indicating that the water flow coming into the pump, heater or salt system is insufficient. Hi Carrie, sounds like an air leak, which is air being sucked into the pump, from somewhere in Front of the impeller, My issue is that the normal operating pressure is around 13-15 psi. 3. I have chalked all the connections and lubricated the basket seal. We had a bad storm and a lot of rain come through. Today, I came home to find my pump off after leaving it on this morning. Upon reading alot of articles and watching videos, it seems the pump came with the clamp on the 115V setting? You could also adjust the pressure switch (on most heaters), to allow it to come on with slightly less pressure, (1 psi instead of 2 psi). Without seeing the union and setup, it is hard to say what is causing it but check for warping of the nut. I just replaced the flow switch and that solved one problem, but now Im only able to produce chlorine when the system is on Super Chlorinate. At no time does the power led turn on. Is there a thicker housing oring that could be installed to fix the leak? I had it replaced. 1. My Hayward pump is only about 3 yrs old. I have a Hayward super flo matrix pump. In particular, if the salt content of your pool water is too high, your metal screws, handrails, ladders, and covers will rust excessively. I couldnt believe it..after two weeks and a new pump! Is the wire the correct size wire? "publisher": {
In some instances, it could just be a bad breaker. If any of these readings are outside limits, replace motor. Products, View This is our second season for this pump. For slide valves (aka push-pull valves), an o-ring on the bottom plunger disk has gone missing or is worn, torn or badly deteriorated. If you vacuumed the floc residue into the filter, you should be able to remove most of it with a thorough backwashing of 5 minutes or so. When it comes to troubleshooting Hayward pool heater error codes, theres not too much difference between the problem solving process for other gas-fired heaters, made by Jandy, Pentair or Raypak. Is the motor set to accept 220V, and matching what you measure at the motor terminals? Articles and resources for swimming pool owners and DIYers. If it sounds loud and grumbly, that can be a sign of cavitation, being starved for water, from not enough water being supplied (it wants more). It does sit in a low spot and has happened once before, but I do have a solution to prevent it from happening again. Its not raw gas, but a sour smell. You must log in or register to reply here. power to my pool pump & timer quit working at the same time. We replaced the handle assembly and valve per Hayward tech support that hasnt fixed the problem. It had a non Hayward motor installed before. Got another one, it too is doing the same thing. Pushing down on the handle briefly (pump off) can often dislodge the debris, and no gasket replacement is necessary if you are lucky. Fingers crossed it is not that! Ryan, is the breaker a 15-amp? 2 yrs is unusual for bearings to go. I first thought it might be the motor capacitor, new cap, problem still the same. Too bad Hayward doesnt make this more clear on their installation instructions and labeling. I dont want to over tighten it. vacuum on waste last night. "height": "219",
Also check all the wires, from the back of the terminal board, to the stat. Read up on it and seems it happens a lot and the motor drive needs to be replaced. Is this enough to cause it not to prime or is there an issue with the impeller? A visual tip-off is something that is dripping water when the pump is OFF, or that sprays water for half-a-second at the instant the pump shuts off, is drawing air in, when the pump is runnning. "thumbnailUrl": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
4. clogged pump impeller I bought a new pump thinking was something wrong with pump on off switch. otherwise all else seems to read ok. Id check the cell number just to confirm it is the TCELL15. Hi Vic, pool pump motors have a thermal overload switch that will shut down the motor if temps get too hot. Profile, Create a Pool Any ideas on how to fix this issue?? We have an Hayward SP1580X15 Power-Flo LX 1.5hp pump. I checked the voltage at the back of the motor and have 240 volts. Also make sure that the pump has no air leaks from loose pipes, loose pump lid, low water level in pool For you Scott, the next step is to shut off power to pump and remove the Blue, Black and Red wires (page 4 owners manual) from the drive and check each motor lead to ground. Hello, I have a H200 natural gas heater . If you need a new one in a few days, I would not consider getting one from Hayward, that could take a month. If not, I would suspect voltage issues, especially with the overheating, be sure pump is wired to accept the incoming voltage (115V or 230V), and it doesnt fluctuate more than 10%, +/- . During that time, the pump got really hot and melted the fitting on the top. Posted: (10 days ago) Posted: (5 days ago) Mountainside Fitness is located at 9375 E Bell Rd, Scottsdale, AZ 85260.Mountainside Fitness can be contacted at (480) 502-2096. Morning , everything was working fine with my Hayward pump. I ended up buying a new Hayward pump online however dont want this to happen again. I connected the pump to a nearby receptacle with a heavy duty drop cord and it works fine. Hello, my salt generator seems to be always be producing at 100% no matter what my output dial is set at. One of them was arguably the best-constructed route from London [Marylebone] to Manchester. My client thinks the motor was 1hp, but he really not sure. Hello, my motor runs for 20 seconds then stops. Switch your cell type by cycling the main switch from AUTO to SUPER CHLORINATE then back to AUTO. I backwash and rinse and start again but it does the same thing. I would also check all the wire connections (power off) to be sure they are tight, on the breaker and on the time clock, and also inspect for insect infestation, or lizards, mice, etc. Hope that helps! Some pumps are stronger than some hose, so check to see if the hose is not collapsing under the suction, during the issue. Most Common areas include the pump lid (must be very tight, with lubed lid o-ring), and the threaded pipe that comes into the FRONT of the pump (must be very tight and sealed if loose, use Pool Putty to fix, or replace the fitting) the effluent or exit pipe fitting leaking will not draw air, that is on the pressure side not the suction side. A check valve could also be a solution, but a Drain King is different, they are used to pressure lines, for blowing out clogged drains usually, but also useful to pressurize the suction manifold to look for air leaks, or for priming a pump that has issues catching prime. If so, shut off power and see if the motor shaft will spin. Clean Gasket (no bits of debris or de powder), 2. Any idea? If you have a visible motor shaft, just behind the impeller, common on older pumps or booster pumps, you can just grab it with straight pliers and turn it back and forth. Poseer una casa es la piedra angular de la riqueza tanto la riqueza financiera como la seguridad emocional. If you can remove the handle, you can apply shaving cream and run the pump to see if it gets sucked in put cream around the stem and on both joints in/out of the valve. Hi, I have a H250PED2. Also look for any burn marks on the wire terminal board, or any crimped wires running round the rear of the motor. You should be able to lift up on the pump just slightly, to push something thin, 1/4 thick or less, beneath it. Hi Mike, pumps are too hot to touch normally, running at 140 or so. "width": "611",
Have zero skills with pool pump filter motors or basically anything associated. Before I purchase all new control board assembly, does this sound about right? Any ideas? But, that may not be it, if you say the shaft is getting stuck each time? filter. Hi Rachel, Im guessing a Hayward Perflex DE filter? Now, if your motor has cooled off, but wont start again, or make any noise at all, as you say i would check the power (volts) going into the motor, put the multimeter probes (set on 240V+) onto the two brass terminals of the motor terminal board, where the two incoming wires connect. I was hoping that you can give me some advice. It is only a 2-3 year old pump. After I installed the ne motor, I pugged it in, started the pump and the breaker tripped. What happens when you switch the output to super-chlorinate? Also check that the stationary switch (6 oclock) and the centrifugal switch (dead center) are not loose or misaligned. We opened our pool a week ago and havent had a problem until today (May 23. "keywords": "",
Fixing this issue can be tricky, so we suggest you get the help of a certified professional. There are pegs all around that prevent moving the wrench beyond 11 and 12 oclock and because the shaft only has two flat sides we cannot get the wrench from another angle plus there are other pegs. It is being practiced by thousands of pool owners just like you. We just opened our pool up cleaned everything out put new D.E. One thing you can attempt is a superglue repair, which I have done successfully on many multiport valves, but not on a pump body. Fourth, check the motor shaft to be sure that it spins easily by hand, fifth, you can check the capacitor (for capacitance), if the motor still isnt starting. Any idea of the problem?? Hi Lo in checking the owners manual https://hayward-pool-assets.com/assets/documents/pools/pdf/manuals/tristar-vs-S3202VSP.pdf?fromCDN=true, it suggests bypassing the timeclock and wiring direct to the breaker. I opened the control panel during a rain storm (down pour) to turn off the filter. You could also use a Hayward 24 sand filter, item E3324. The article says: The electrician checked wiring and installed new breaker and does same thing. Still same though nothing being sucked through basket and minor trickle back out into pool. Samsung Da29-00020b 3 Pack, Thanks. The leak and the surging you are experiencing, could be a result of the high filter pressure. Hi Bryan, not normal but not uncommon. If I let it sit I can turn it on again, but just for about 20 seconds. Students and professors will find thorough, current coverage of all business research topics presented with a balance of theory and practical A Answered on 5/26/2022 by InyoPools Product Specialist Craig C.. Hello J. That is usually suitable, but 20 amp could also be used. Maybe the transformer is not functioning properly? Is the wire size correct? Check that the motor wiring matches input voltage, if the motor can be wired 110/220V. If the pump is on high when it is supposed to come on the pump motor humms and cuts off. Then check the GFCI for loose wires. Anyway I decided to run it and it appears that the pump runs full power with the returns pushing out with lots of force for about 5 minutes and then it weakens. A start capacitor is supposed to only be energized for a few seconds to start the motor, and once the centrifugal switch opens and releases contact with the stationary switch, the capacitor is released. The motor on my Hayward super pump 2 went out so I ordered a Hayward replacement. We opened our pool today, and when we went out to turn off the Hayward pump, after it ran for 7 hours, the plug was so hot it burned my fingers when unplugging it. Be sure the wiring is tight on both ends. Yes, kind of does defeat the purpose, but you may not need to heat the pool all the time, so can still run on low-speed for many hours per day. Can it be repaired or do we need a new pump? You can use a bent paperclip to ream out the orifices. What do you think is the problem? Again, flow rate is good but it doesnt make the change in pressure like it should when switching to sweeper. Sometimes this can be cleared or removed, without pulling the pump apart, which is def. To fix the problem, manually reset the Inspect Cell LED. What can I do? 3. inspect clock and rear of motor for any obvious signs of damage, like watermarks, dirt, insects or something burned or melted The motor may be dead, or possibly not. 5. Hayward pumps use different shaft seals, you can find the correct one here: https://www.intheswim.com/c/pump-parts?pcode=208&scode=SOCIBLOG . Is this the proper way to wire this salt water panel or does it also have to have a cable going into N0-2? Now when we try to turn everything on the pump wont start at all and keeps tripping the breaker. Hi Jeanette, somewhat normal with sand filters I would say first. Any insight? Any ideas? Went to clean the pool filter a few days later and now when turning on the pump it made a loud grinding noise. Thank you Hi Stephen, your spa waterfall, is that a spillover or an actual waterfall feature? Thanks. Hi Shannon, well thats encouraging. Silicone lube can also be used, but dont use petroleum based lubes that can eat the rubber. 24V after the transformer is present. We live in Arizona, so the automatic freeze setting isnt an issue. If still stumped, use a power meter to find the problem lies where the power dies, and trace power from the breaker to the timer or outlet, to the motor. Hola tengo una caldera Hayward H400 PED2 durante el intento de encendido no enciende m caldera despus de 5 intentos me pone lF en la pantalla. Any suggestions welcome. That is the black cylinder in the rear of the motor, located at 9 oclock. Flow switches require a minimum flow fate of 11 gallons per minute to stay consistently closed, Water temperature is below 50 degrees F. (The cell output scales back to 20% once it reaches 60 degrees F and shuts off at 50 degrees F.). Shut it off & starting looking for help online. This week the motor Your thoughts? Are you getting 230V (207v 253V) at the pump? If you have a filter pressure gauge, the practice is to clean the filter when the pressure gauge rises 7-9 psi above the clean, starting pressure. My pump seems to trip the GFCI breaker each time it is plugged in. If you program an incorrect cell size, the salt level, amperage, and voltage will not be correct and the system will turn off. "address": "",
Also they winterized the place where the water circulates inside the pool and it wont unscrew so we can let some of the water out and put the original piece back on. Almost ordered a new pump but it really sounded good. Hi Ric, is the SF service factor rating the same on both motors (new and old)? I have a Hayward pump and filter system for my outdoor water feature. I have a Hayward SP2607x10 pump with a Hayward C48k2n143B1 self priming super pump. The cell amperage is above the maximum limit. Could possibly be loose wires on the motor or timer, possibly a loose centrifugal switch or stationary switch on the motor, or maybe the windings in the motor are shorting out. I need some advice for my 15 x 30 x 48 AG oblong swimming pool. Check that the shaft spins freely, and check that the triangular switch at 6 oclock in the back of the motor, is tightly screwed, and that the centrifugal switch, located in the center, on the end of the rear shaft, is also tight, and that the two switch tabs are in contact with each other in the center. Do I need to clean filter? Maybe the breaker is loose on the bar, or perhaps insects shorting it. outlet still on. Hi Bobby, so you have power at the motor, but no noise. It is quite rare that while testing a capacitor, it explodes (small explosion), but it can happen. Zero on the gauge indicates no water flow, so if not an air leak it could be a clogged line, pump basket or impeller. Rust can develop inside the motor that you can break free, by spinning the shaft a few times. Im having an air leak problem with my pool. If you are getting correct voltage into the rear of the motor (120V or 240V, +/- 10%), but still the motor makes no noise at all, its likely DOA the motor at least. Hi Cortney, you can buy the cord separately, Hayward pump cord the cause is likely from something arcing within the plug outlet. Typically, the LED light should shut off after 60 seconds. Ive checked out your blog and you had very good info for audience. On the return side, after the heater, the return valve should also move, with Spa Jets fully open and pool returns fully closed. It could also be a clogged impeller or clogged filter, or clogged skimmer line. Hi Keri, I understand, with Hayward Valves, incl the most common top mounted sand filter valve SP0714T, have the Spider Gasket molded to the underside of the rotor. If the pond is located below the pool equipment, then the pump and filter and pipes will drain down to that level, once the drain plugs are removed. My diffuser does not tightly fit into my seal plate. Hi Michael, that could be a bad or weak capacitor, or a loose wire to the pump motor or to the outlet, or a bad power cord. Check it out, it could start a fire! The pump/motor, is a power flow LX, 1.5 HP, model SP151521BC, & the Sand Filter is the pro series model S210T. Can you help? Following this procedure will identify LibriVox About. anyway I digress. Replace with the exact same MFD number printed on the capacitor. If you are plugging and unplugging the pump to turn it on/off that could cause the problem over time. Hi Anessa, Hayward VS pumps are known to have Drive Errors, whereas Pentair, I dont hear so many problems about the Intelliflo. You can remove the wires and call your local Electric Motor Repair Shop, and see if they have this capacitor in stock, just read them the MFD number range printed on the side of the black cylinder. If the pump makes no noise at all, turn on power, and with a multi meter, check the power at the pump, switch/timer and breaker, the problem lies where the power dies. Pump is 4yrs old. Poor connection inside the plug or socket. Sounds like a leak from the shaft seal, although it could be dripping from the pipe carrying water out of the pump, running down and dripping off the bottom. Check for water under the display, or in the control box area. Thinking its the compressor or really dont know at this point. 1. New motor sounds like the thermal overload switch (located at 12 oclock in the rear of the motor) is shutting off the motor, which is usually not a good sign, and mostly means the pump is on its way out. If lots of air churns when you shut the pump off, and the water quickly blasts out of the pump, thats likely a suction side air leak. The pump should really be on its own breaker if possible. If voltage is normal, there may be a loose wire in the motor, perhaps behind the terminal board, or a bent wire that is touching some metal housing, or bent and touching another wire. 240v Input voltage is present. The water is probably not related, but yeah, may be a loose hose or if not, then likely a bad shaft seal. All-In-One Sanitization Hi, Humming Motor: If the pump motor makes a humming sound when starting up, you likely have a clogged impeller. I have a Hayward sp 2603 vsp pump which is a year old has been working fine but 2 days ago I turned it on it ran about 1 minute, it cut off and on the display it says error code 11 and it will not run. Camfrog Pro Extreme Atau Gold - Camfrog Indonesia. We tried opening the pool today when we plugged in the Hayward filter it keeps blowing the circuit breaker. Automatic reset is immediate after error is corrected. The pool seems to be bonded,I did find that the Aqua Logic Panel is fed from the main electrical panel has no equipment ground, when I established a ground, the motor shortly after burnt up, heard a little crakling and a pop in the motor housing, and little smoke (the breaker did not trip, until the pump smoked out it seemed to be running fine, with a normal amp load. Also, I wonder if it matters or not which filter would be best, the Hayward EC50AC (AG), or sp2607x10 EC65A (IG). Step 3: Double check the wires on the flow switch for damage. After filter was fully re-assembled- pump would turn on. Yesterday the breaker tripped. Hi Toula, consider that the impeller may be clogged, or you may have an air leak, in front of the impeller. You will have a choice of replacing the bearings or having a local electric motor shop do it, or replace the entire motor, or the entire pump. Most heaters can operate on 120V/240V, either one. ), 2) the pump lid o-ring (is it lubed? We are getting a reading o the remote stating chlorinator is turned off High Temperature. Found this blog, followed the instructions by removing the capacitor and thermal overload, turnied the shaft with a 7/16s. Hi Mike, when there is no wiring diagram printed on the motor label or above the nameplate, indicating High/Low Voltage wiring specs, then the motor is not reversible. Now if your pressure is jumping up to 20 psi very rapidly (hours or days), the filter media (sand, de or cartridge) may need to be replaced. This is weird, no? The pump is only one year old. Its concerning to suddenly hear strange sounds coming from your Hayward pool pump. When pumps dont run for a long time, they are susceptible to rust forming in between the stator and rotor. Any idea how to correct this. Check the capacitor, for bulging, cracking, or melting. I did the shaving cream trick and no air leak detected. Hi Bill; So you have power coming into your timer or timeclock, but on the out terminals, or the wires that lead to the pump? The pipe from the pump is connected to the valve in the port labeled PUMP and the pipe returning to the pool connects to the port labeled RETURN. Disconnected the chlorination device, and direct connected it eliminating that. If it is a 15amp breaker, but the pump wants 9amps and the aquatrol wants 7 amps, (for example, made-up numbers) thats a total of 16amps, too much. I tried to restart them & only got a low buzzing type noice. Thanks. Find answers to your questions about all The original pump (assy A) smells burnt. Also, DE filters need to be opened up and hosed down completely clean every 6-9 months, and then started up again with a full charge of DE powder. There is water under the motor not sure from where. i hope this helps, but I am also maybe missing something. Enzyme treatment to the pool can remove oils (if the sand seems oily), and Stain & Scale chemicals can tie up minerals like calcium (if the sand seems crusty). Cleaners Controls Filters General Pool/Spa Heat Pumps Heaters Lighting Pumps Robotic Cleaners Sanitization Step 3: Select model to register. That is usually what causes the rattle. You can also order capacitors online. There was a slight drip coming from a fitting, that I tightened. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
Also, if there is a GFCI outlet connected, perhaps it is tripped? A longstanding legal battle over control of the old Apex Department Store properties in Pawtucket appears to be headed.. Apex Legal Funding is a lawsuit financing company that provides pre settlement funding and post settlement funding to plaintiffs.